• Post author:
  • Post published:
  • Post category:News
  • Post comments:0 Comments

SUPERIOR FLUID SOLUTIONS · ORDERING GUIDE

Inline Filter Elements: Replacement and Micron Rating

How to read a micron rating, match an element to its housing and decide when to change it.

11IF element part numbers on the Superlok® element page
0.5 to 90 µmrange of element ratings listed on that page
4 checksrating, housing, material and pressure drop

Ordering an inline filter element is a matching job: the rating, the housing and the material all have to line up before the part number means anything. According to Machinery Lubrication, a lubrication trade publication and not a manufacturer or distributor, a nominal rating is “an arbitrary micrometer value given to the filter by the manufacturer.” Our inline filters category lists both filter bodies and replaceable elements, and this guide explains how to choose between them.

Ratingnominal or absolute?
Housingwhich element fits
Materialask in writing
ΔPthe change signal

How to read an inline filter element’s micron rating

A micron figure on its own does not say how many particles of that size are stopped. Machinery Lubrication explains that an absolute rating “gives the size of the largest particle that will pass through the filter or screen,” while a nominal rating is set by the manufacturer. It adds that no standardized test method exists for absolute ratings, though they better represent filter effectiveness than nominal ones.

The same article describes the beta rating as the most commonly used industry measure. It comes from the ISO 16889 multipass test, and it is the upstream particle count divided by the downstream count at a stated size. Efficiency is (beta minus 1) divided by beta, times 100, so a beta of 10 at five microns is 90 percent efficient. It cautions that a beta ratio does not show dirt-holding capacity.

Superlok® lists each SIF filter with a micron rating and a pore size range. Those pairs are the useful part, because they show the rating is a single number sitting inside a band. The listing does not say whether the rating is nominal or absolute, and it gives no test method or efficiency, so ask for that in writing if your service depends on it.

Element ratings in the Superlok® listingfrom the manufacturer’s SIF and IF pages
Rating Pore size range on SIF listing Element part numbers listed
0.5 µm 0.5 to 2 µm IF1-ET-0.5, IF2-ET-0.5, IF3-ET-0.5
2 µm 1 to 4 µm IF1-ET-2, IF2-ET-2, IF3-ET-2
7 µm 5 to 10 µm IF2-ET-7, IF3-ET-7, IF4-ET-7
60 µm 50 to 75 µm IF2-ET-60
90 µm Not stated IF2-ET-90

Source: Superlok North America, SIF inline filters and IF filter elements pages. Neither page names nominal or absolute rating.

Matching the element to the housing

Superlok® presents its SIF inline filters as having stainless steel construction with replaceable elements. The housing page that loaded lists SIF1, SIF2 and SIF3 series, while the element page lists IF1 through IF4 part numbers. The element page also describes every part, including the IF2, IF3 and IF4 numbers, as a filter element for the SIF1 inline filter. That may be a labelling quirk, so settle it before buying.

The practical rule is to order against the housing part number you have installed, not against the micron rating alone. Send the full housing part number, the tube size or thread on its ports, and the rating you want, and we confirm which element fits before the order is placed. If your drawing is metric, ordering metric tube fittings from an imperial drawing covers the conversion traps.

Remember that the housing sets the pressure limit. For the SIF1 and SIF2 series, the Superlok® page gives a working pressure of 206 bar (3000 psig) from -20°F to 100°F, falling to 116 bar (1690 psig) at 850°F. For the SIF3 series it gives 172 bar (2500 psig) at the cooler end, falling to 97.1 bar (1410 psig) at 850°F. A new element does not change those numbers, so check the service temperature as well as the pressure. Our inline filter page lists bodies and replaceable elements.

Element material: what the pages do and do not say

The Superlok® pages we fetched do not state the element material. They describe stainless steel construction for the SIF line, and that is all. So material is a question to ask, not assume. For corrosion-resistant service, ask for the element material in writing, and match it to the fluid the same way you would match a seal.

If you need documents with the order, say so at the quote stage. Our post on material test reports for fittings sets out what to request. If a part is listed in 316 stainless steel, we still confirm its grade and rating per order. On cleanliness, the manufacturer’s position is that Superlok® offers the finest interior surface finish of any tube and pipe fitting on the market.

When to change an inline filter element

The signal is differential pressure, the drop between the inlet and the outlet. Pall, a filter manufacturer, notes that as contaminants collect, the flow restriction through the element increases, so a higher pressure drop means a more clogged element. It adds that readings are only accurate under flow.

Power & Motion Tech carries an article by a HYDAC product manager on hydraulic filters. It says the element "should be changed as soon as the indicator trips," and that the indicator is usually set about 15 psid (1 bar) below the bypass pressure. It puts the interval from indication to bypass at typically 5 to 15 percent of element life.

Those figures describe hydraulic filters with indicators and bypass valves. The Superlok® pages for the SIF line mention neither, and no source we fetched gives a change interval for any instrument filter. So set your own trigger. Record the pressure drop across a new element at normal flow, read it the same way each round, and change the element when the drop rises to the limit your engineer chooses. A gauge valve at each side of the filter makes that reading simple and keeps the line in service.

Keep one spare element of the rating you use for each installed filter. If a part is late, the back-ordered fitting options apply to elements too.

Questions about replacing elements

Is a finer micron rating always better?

Not by default. A finer rating is a tighter specification, not an upgrade. Choose the rating your process requires and confirm it with your engineer.

Can I tell if my element is nominal or absolute?

Not from the Superlok® pages we fetched, which give a rating and pore size range only. Ask for the rating basis in writing before you rely on it.

How often should I change an element?

The sources give no interval for these filters. Use differential pressure from a baseline reading on a new element, and change at the limit you set.

What do I send to order the right element?

The installed housing part number, the rating wanted, the service fluid and temperature, and whether documents are needed. We confirm fit before the order.

Does a new element raise the housing’s pressure rating?

No. The housing page sets the working pressure by series and temperature, and the element does not change it.

Send the housing number, we match the element

Include the rating you need and the service conditions.

Request a Quote →

SUPERIOR FLUID SOLUTIONS

The right element starts with the right housing number.

Sources

  1. Jeremy Wright, “Understanding Filter Efficiency and Beta Ratios,” Machinery Lubrication, undated. Supports the nominal and absolute definitions, the absence of a standardized absolute test method, the ISO 16889 beta rating, the efficiency formula and the beta 10 example. machinerylubrication.com
  2. Superlok North America, “SIF Inline Filters.” Manufacturer publication. Supports the stainless steel construction, the micron ratings and pore size ranges, and the working pressures by series and temperature. superloknorthamerica.com
  3. Superlok North America, “IF Filter Elements for SIF Inline Filters.” Manufacturer publication. Supports the 11 IF part numbers, the ratings from 0.5 to 90 micrometers and the SIF1 housing description. superloknorthamerica.com
  4. Pall Corporation, “Differential pressure.” Filter manufacturer publication. Supports the rising restriction as contaminant collects and the need to read under flow. pall.com
  5. Jeff Ruth (HYDAC Technology Corp.), “Condition monitoring made easy,” Power & Motion Tech, 21 May 2013. Written by a manufacturer’s product manager. Supports the change-at-indicator statement, the 15 psid setting and the 5 to 15 percent figure. powermotiontech.com

Technical note: Machinery Lubrication establishes how nominal, absolute and beta ratings are defined in general, not how any Superlok® element is rated. The Superlok® pages list ratings, pore size ranges, part numbers and housing pressures, and they do not state the element material, the rating basis or a change interval. The Pall and HYDAC material concerns hydraulic and industrial filters with indicators, so applying it to a small instrument filter is our reading. Nothing here is a price, stock level or lead time, and grade and rating are confirmed per order.

Trademark disclaimer: Superlok® is a registered trademark of its owner. Superior Fluid Solutions is a stocking distributor and is not affiliated with Machinery Lubrication, Pall Corporation, HYDAC or Power & Motion Tech. Cross-references are made by form, fit, and function only.

Leave a Reply