SUPERIOR FLUID SOLUTIONS · DIAPHRAGM VALVES
Cross-Referencing a GEMÜ Diaphragm Valve
A GEMÜ part number can point to a process valve or a high-purity one, and only the second is a candidate for a cross-reference.
A GEMÜ diaphragm valve part number can point to two very different products, and a cross-reference only makes sense for one of them. Superlok® diaphragm valves are high-purity instrumentation valves, so they can be compared only with the comparable GEMÜ high-purity range, never with large-bore process valves. Begin with the body material, connection and size on the GEMÜ data sheet, then read our diaphragm valves page for the Superlok® side. According to GEMÜ’s own product brochure, a manufacturer publication, its diaphragm valves run from DN 4 to 100 in plastic and DN 4 to 300 in metal, with operating pressure up to 10 bar.
Which GEMÜ Diaphragm Valve Are You Holding?
GEMÜ’s own pages sort its diaphragm valves into groups that serve different jobs. Three matter here.
The general range covers process, sterile and abrasive media. The data sheet for the 687 shows what that looks like: a pneumatically operated metal valve from DN 10 (NPS 3/8) to DN 100 (NPS 4), offered as normally closed, normally open or double-acting, with butt-weld spigots, threaded sockets, flanges and clamp ends including ASME BPE styles. The sheet does not mention semiconductor service.
The metal aseptic group is described as primarily for sterile applications in pharmaceutical, food and biotechnology plants, and also for ultra pure media in semiconductors, microelectronics and fine chemicals.
The ultra-pure plastic group is the one aimed at semiconductor tools and chemical supply. GEMÜ names the CleanStar, PurePlus and iComLine ranges, with bodies in PFA, PP-H and PVDF and a PTFE/EPDM diaphragm, produced under cleanroom conditions in Switzerland.
Where a Cross-Reference Applies and Where It Does Not
On its own page, Superlok® presents these valves as electro-polished and DI-water cleaned, with assembly, testing and packaging done in a certified clean room, and aims them at shut-off isolation in gas control and analyzer sampling systems. That sets the comparison. A GEMÜ process valve with flanged or sanitary clamp ends in a DN 50 or DN 100 body belongs to a different class, and we will say so instead of quoting an alternative. The plastic ultra-pure group is not a stainless steel comparison either, because its wetted parts are PFA, PP-H or PVDF. What remains is a GEMÜ high-purity valve in metal, on connections and in a size you can set beside the Superlok® data sheet.
What to Read on the GEMÜ Data Sheet
Take the figures from the sheet for the exact ordering code on your valve. The table uses the 687 sheet as an example of what each line can tell you.
| Line | What the sheet shows | Why it matters |
|---|---|---|
| Size | DN 10 to DN 100 | Large bodies sit outside the instrumentation class |
| Ends | Weld spigots, threads, flanges, clamps | Flange and clamp ends point to process piping |
| Body | 1.4435 (316L) forged or cast, plus other grades | Grade is confirmed per order, not assumed |
| Pressure | 0 to 150 psig at DN 10, normally closed | Varies with actuator, function and diaphragm |
| Flow | Cv in gpm at 75 psi inlet and 1 psi differential | Compare only on the same stated basis |
From the manufacturer’s data sheet for the 687. Your valve will differ, so use its own sheet.
On flow, the 687 sheet states that its Cv figures were measured with a stainless steel forged body and a soft elastomer diaphragm, and that the flow curve varies with diaphragm material and duration of use. It publishes no cycle count, and says repeated high-temperature sterilization shortens diaphragm life.
Actuator, Diaphragm and Cycle Questions
The actuator half of the order is a separate decision from the body. Our earlier guide to buying a pneumatic diaphragm valve covers rest position, supply pressure and how to read cycle-life claims, and the same questions apply to a GEMÜ valve. Diaphragm material also sets media and temperature limits: the 687 sheet lists 14 to 194 °F for FKM and 14 to 212 °F for EPDM variants.
Sending a GEMÜ Part Number to Superior Fluid
Send the full ordering code from the valve label, the body material, size and connection, the operating pressure and the fluid, and say whether the valve is a process or a high-purity model. Drawings in DN need translating to tube sizes, which is the subject of a separate guide to metric tube fittings against an imperial drawing. Quality paperwork is covered in the material test report note, and welded joints on a high-purity line are on the UHP weld fittings page.
Superior Fluid’s shop lists no diaphragm valves, so a valve request goes through the quote form. When the answer is that a GEMÜ valve has no comparable Superlok® valve, we will say that. Around the valve, Superlok® tube fittings provide the finest interior surface finish of any tube and pipe fitting on the market. Stainless steel is corrosion-resistant but not universally so, which is why the fluid goes on the request.
GEMÜ Valve Questions
Can any GEMÜ part number be cross-referenced?
No. Only a high-purity valve in a comparable body, size and connection is a candidate, and then by form, fit and function after the data sheets agree.
Is the GEMÜ semiconductor group made of stainless steel?
The ultra-pure plastic group GEMÜ lists for semiconductor use has PFA, PP-H or PVDF bodies. Check the sheet for the exact code.
Which flow coefficient should I compare?
Only values stated on the same basis. The 687 sheet gives Cv at 75 psi inlet and 1 psi differential, and says the curve varies with diaphragm material.
Can I order a diaphragm valve from the shop?
Not at present, since the shop lists none. Use the quote form and attach the data sheet.
Send the Data Sheet, Not Only the Number
Ordering code, body, size, ends and pressure get you a straight answer, including when the answer is no.
SUPERIOR FLUID SOLUTIONS
Plain about what compares and what does not.
Sources
- GEMÜ, “Valves, measurement and control systems” product brochure (manufacturer publication, file dated 29 September 2023), for the diaphragm valve size range, pressure, temperature and the process, aseptic and globe valve groupings. gemu-group.com
- GEMÜ, “687 Diaphragm Valve, Metal Construction” data sheet (manufacturer publication, file dated 22 July 2021), for sizes, control functions, connections, body materials, Cv basis, temperature limits and the absence of a cycle count. gemu-group.com
- GEMÜ, “Ultra pure plastic diaphragm valves” page (manufacturer publication), for the CleanStar, PurePlus and iComLine ranges, PFA, PP-H and PVDF bodies, PTFE/EPDM diaphragms and cleanroom production. gemu-group.com
- GEMÜ, “Metal aseptic diaphragm valves” page (manufacturer publication), for the sterile, pharmaceutical, food, biotechnology and ultra pure applications. gemu-group.com
- Superlok North America, “UHP Diaphragm Valves” page (manufacturer publication), for the electro-polished, deionized-water-cleaned, clean-room assembled description and the gas control and analyzer sampling uses. superloknorthamerica.com
Technical note: The sources establish how the manufacturer describes its diaphragm valve groups and what one data sheet, the 687, publishes for sizes, connections, materials and flow basis. They do not establish which GEMÜ range, if any, compares with a given Superlok® valve, because the Superlok® page reviewed gives no size, pressure or actuation figures. A comparison therefore rests on data sheets for the exact codes. Grade and rating: confirmed per order.
Trademark disclaimer: GEMÜ is a trademark of GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG, and CleanStar, PurePlus and iComLine are product range names used by GEMÜ. Superlok® is a registered trademark of its owner. All other names belong to their owners. Cross-references are made by form, fit, and function only.