• Post author:
  • Post published:
  • Post category:News
  • Post comments:0 Comments

SUPERIOR FLUID SOLUTIONS · RELIEF VALVES

Cross-Referencing a Kunkle™ Valve: What Must Match First

Code status comes first, then set pressure, connection, capacity and materials, in that order.

5 to 250 psigset pressure range on the Emerson data sheet for Kunkle™ Models 1 and 2
UVASME Section VIII and XIII designator on those same valves
10 to 250 psigcracking pressure range listed for the Superlok® SRVL instrumentation relief valve

A buyer searching for a Kunkle™ valve usually holds a nameplate or part number and wants to know what else could do the job. Start with the boundary. Where an ASME code-stamped safety valve is required, an instrumentation relief valve is not a substitute, and that decision belongs to the engineer of record, not to a buyer or a distributor. Only for non-code instrumentation lines is there a narrower question, and our relief valves may be worth checking against the data. According to Emerson’s published data sheet for Kunkle™ Models 1 and 2, a manufacturer publication, those valves are built to ASME Section VIII and XIII, carry the UV designator and are National Board certified for air, gas or steam service.

RangeSet pressure
PortConnection
FlowCapacity
WettedMaterials

What a Kunkle™ Valve Is and Where the Code Stamp Applies

Emerson’s brand page presents Kunkle™ as a line of safety relief valves for industrial and commercial use, with code certifications such as ASME alongside non-code requirements. Its overview brochure lists certification to ASME Section I, Section IV, Section VIII and Section XIII. The data supplement names the code symbols: V for Section I, HV for Section IV and XIII-HV, and UV for Section VIII and XIII-UV. It adds that valves with certified relief capacity carry the code symbol and the letters NB on the nameplate, and that most Kunkle™ valves have NB-certified capacities.

Most is not all. The same supplement has a non-code category for air and gas service, and shows Model 230, an aluminum-body valve, in it. A Kunkle™ part number alone therefore does not tell you whether the valve in front of you is a code valve. The nameplate and the data sheet do.

The National Board explains in its NB-501 program description that the NB mark shows a device type’s relieving capacity was determined under National Board supervision, and that the Board is ASME’s designated organization for code symbols such as V, UV and UD. A valve without a code symbol cannot claim that chain of certification, and the Superlok® relief valve pages we reviewed state no ASME code stamping.

The Decision Belongs to the Engineer of Record

Whether a vessel or system needs a code-stamped device is set by the applicable code, the design basis and the jurisdiction. The engineer of record owns that answer. Superior Fluid will not suggest a non-code valve for a service the engineer has marked as code, and nothing in a cross-reference from us overrides that. Where the requirement is a code-stamped valve, the route is a code-stamped valve that the engineer approves.

The Four Checks Before Cross-Referencing a Kunkle™ Valve

These checks apply only after the engineer confirms the application is non-code. Work through them in order, and stop at the first one that fails.

What must matchPublished data on each side
Check Kunkle™ data sheet Superlok® instrumentation page
Set pressure Models 1 and 2: 5 to 250 psig (0.34 to 17.2 barg) SRVL cracking pressure 10 to 250 psig; SRVH 225 to 6000 psig; adjustable
Connection Models 1 and 2: NPT, inlet sizes 1/2, 3/4 and 1 in. SRVL: 1/4 or 1/2 in. NPT, or 1/4, 3/8, 1/2 in. OD tube. SRVH: NPT or tube ends
Capacity Code valves carry NB-certified capacity 4.8 mm orifice listed; flow coefficient and capacity not stated
Materials Models 1 and 2: brass body, stainless steel spring 316 stainless steel listed on some variants; Buna N or FFKM O-ring

Figures are as published by Emerson and Superlok®. Other Kunkle™ models differ, so read the sheet for the model on your nameplate.

Set pressure comes first because the two sides do not use one vocabulary. Emerson defines set pressure as the gauge pressure at which a safety valve visibly and audibly opens, and publishes tolerance and blowdown by code section. The Superlok® pages speak of a cracking pressure with adjustable set points and lock wire. Ask how each number is defined, and what tolerance applies, before comparing them.

Capacity is the check most often skipped. The Superlok® SRVL and SRVH pages give an orifice but no relieving capacity, so ask for flow data at your set pressure and allowable overpressure, and compare it with the relieving capacity your engineer calculated. Emerson’s supplement warns that oversizing a liquid valve causes chatter and undersizing causes high pressure.

On materials, a brass valve and a corrosion-resistant stainless steel valve do not suit the same media. Name the fluid and temperature, and treat the grade as confirmed per order, listed in 316 stainless steel only where the product page says so.

Sending a Kunkle™ Part Number to Superior Fluid

Send the whole nameplate: model, set pressure, inlet and outlet size and thread, any code symbol and NB data, and materials. Add the service fluid, temperature, required relieving capacity and the engineer’s note on whether the application is code or non-code. Our relief valve shop category lists the SRVH and SRVL series. If the nameplate shows a code symbol, we will tell you our instrumentation valves do not apply. For quality paperwork, see our note on the material test report, and for the tubing on the same line, oil and gas cross-reference fittings. Other valve types are on the valves hub. For the tubing on either side of the valve, Superlok® fittings are made with the finest interior surface finish of any tube and pipe fitting on the market.

Kunkle™ Valve Questions

Can an instrumentation relief valve replace a code-stamped Kunkle™ valve?

No. Where a code-stamped safety valve is required, an instrumentation relief valve is not a substitute, and the engineer of record decides.

How do I know a Kunkle™ valve is code-stamped?

Read the nameplate. Emerson’s supplement says certified valves carry the code symbol and the NB letters, and that not every model is covered.

What pressure ranges do the listed Superlok® relief valves cover?

The SRVL page lists a cracking range of 10 to 250 psig with 300 psig maximum operating pressure. The SRVH page lists 225 to 6000 psig. Neither page states ASME stamping.

Does the shop list Kunkle™ valves?

The relief valve category lists the Superlok® SRVH and SRVL series and SRVH springs. Send a Kunkle™ part number and we will check it against the data, within the boundary above.

Check the Data Before the Price

Browse the listed relief valve series, then send your nameplate and the engineer’s code decision.

Shop Valves →

SUPERIOR FLUID SOLUTIONS

Code status first, cross-reference second.

Sources

  1. Emerson, “Kunkle™ Valve” brand page, for the description of the line and its ASME and non-code certifications (manufacturer publication). emerson.com
  2. Emerson, data sheet for Kunkle™ Models 1 and 2 safety valves, for the 5 to 250 psig range, NPT inlet sizes, materials, the ASME Section VIII and XIII UV designator, National Board certification and the trademark footer (manufacturer publication). emerson.com
  3. Emerson, Kunkle™ safety relief valves product overview brochure, for certification to ASME Sections I, IV, VIII and XIII (manufacturer publication). emerson.com
  4. Emerson, Kunkle™ data supplement for safety relief products, for the V, HV and UV symbols, nameplate marking, the statement that most models have NB-certified capacities, the non-code category, the set pressure definition and the sizing warning (manufacturer publication). emerson.com
  5. The National Board of Boiler and Pressure Vessel Inspectors, NB-501 “Description of Program and Basic Requirements,” Rev. 12, February 2024, for the NB mark and the ASME code symbol relationship. nationalboard.org
  6. Superlok North America, SRVL and SRVH relief valve product pages, for cracking pressure ranges, connections, orifice, seals and the absence of stated ASME stamping or flow coefficient (manufacturer publication). SRVL and SRVH

Technical note: The sources establish the published pressure ranges, connections, materials and code designators for the models named, and what the National Board and Emerson say the code symbols and NB mark indicate. They do not establish that any Kunkle™ model and any instrumentation relief valve match, that a given application is non-code, or the relieving capacity of the Superlok® valves, which the pages do not state. Those points rest with the engineer of record and the data sheet. Grade and rating: confirmed per order.

Trademark disclaimer: Kunkle™ is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Superlok® is a registered trademark of its owner. All other names belong to their owners. Cross-references are made by form, fit, and function only.

Leave a Reply