SUPERIOR FLUID SOLUTIONS · HYDROGEN
What a Mobile Hydrogen Refueler Needs on the Fitting Side
A skid-packaged fuelling unit is built once and repeated, so the fitting and valve list should be written once too.
A mobile hydrogen refueler arrives as one package: the tank, pump, dispenser, controls and safety systems are built into a single unit and trucked to site. According to Hyroad Energy’s press release of 29 July 2026, a company publication, its Santa Fe Springs, California station combines a 1,000-kilogram liquid hydrogen tank with those same elements in one mobile unit, and logged 45 fuelling transactions in its first full week. For the buyer behind a unit like that, the question is which tube fittings, valves and gauges go on it, and whether the list can be bought the same way every time. Our guide to high pressure hydrogen fittings covers the metal and the ratings. This post covers the kit.
Why a mobile hydrogen refueler is bought as a kit
The Hyroad release says the unit is a way to bring new fuelling capacity online while permanent stations are developed and constructed, and that Hyroad is building a network across California and Texas. It reports fuelling times consistently under 25 minutes. A second example comes from Toyota Motor North America: its news release of 20 October 2026 says Toyota has installed two mobile hydrogen fueling devices at its North American Parts Center California and plans a permanent station there.
Neither source says how many units will follow, so we do not forecast a number. What both show is a bridge product that goes in ahead of a permanent build. A unit built to one design has one bill of materials, and that is the reason to hold the list as a kit and revise it in one place.
Start from the pressure class, not the product name
The Hyroad release states no dispensing pressure, so we attribute none to that station. The first line of any kit sheet has to come from the unit builder, not from us. For context, the U.S. Department of Energy’s Alternative Fuels Data Center describes two classes: H35, which is 35 megapascals or 5,000 psi, and H70, the 10,000 psi class. It notes that light-duty fuel cell cars carry 10,000 psi tanks and buses carry 5,000 psi tanks. Converting, 35 MPa is 350 bar and 70 MPa is 700 bar.
Ask for the maximum working pressure of each circuit, because the supply, pump discharge and dispenser lines will not share one figure. Then compare ratings as numbers. Superlok North America lists its SRVH relief valves with a maximum operating pressure of 6000 psig, which is below the 10,000 psi class, so that series would not suit a circuit at that level. It lists SHBNV bar stock needle valves at 10000 psi. A nominal figure still leaves no margin to read, so the exact configuration is confirmed per order against the circuit pressure.
Material and temperature on a liquid hydrogen unit
The Department of Energy’s Safe Use of Hydrogen page warns that some metals can become brittle when exposed to hydrogen. H2Tools, an educational hydrogen safety reference whose page does not name its publisher, lists welds, surface flaws, stress, hydrogen pressure and temperature among the variables, and adds that for liquid hydrogen service, low temperature embrittlement is also a consideration.
For a buyer, that means not assuming one fitting suits every point on the skid. The line leaving the cold tank and the line to a dispenser may see very different temperatures. Put a service temperature and a pressure beside every part on the kit sheet, and treat any part without both as unspecified. Our material test report post explains the paperwork that records the grade.
Fewer joints, and a unit that moves
The Department of Energy notes that hydrogen is much lighter than air and dissipates rapidly, and that adequate ventilation and leak detection are important elements in the design of safe hydrogen systems. A fitting list supports that design in two ways. Fewer joints mean fewer places to leak, and each joint that remains should be one your crew can make and remake the same way every time. A unit that is trucked to site also travels, so plan to inspect joints after transport and carry spare ferrule sets. Our note on buying and stocking ferrule sets covers what to keep on the shelf.
| Section | Settle first | Put on the kit sheet |
|---|---|---|
| Tank connections | Service temperature, pressure | Isolation valves, tube fittings, relief valves |
| Pump and transfer | Discharge pressure | Tube fittings, check valves, gauge valves |
| Dispenser | Pressure class, hose and nozzle ends | Needle valves, quick connects, tube fittings |
| Controls | Tube OD, thread type | Instrument tube fittings, manifold valves |
| Safety systems | Set pressure, vent routing | Relief valves, tube fittings for vent lines |
Our checklist, built from the section names in the release. It is not a Hyroad bill of materials.
Turning the sheet into a quote
Once each line carries a pressure, temperature and connection, the sheet can be priced as a set. Superlok North America describes its line as having the finest interior surface finish of any tube and pipe fitting on the market. Our relief valves and needle valves pages show the range, and the relief valve shop shows what is listed in 316 stainless steel. A corrosion-resistant grade is only the start, because the pressure rating and the hydrogen duty still decide the match.
If one line goes out of stock at a vendor mid-build, the whole unit waits. Our back-ordered fitting post covers what to do. Send the finished sheet through the quote form and we will respond line by line, with quantities and delivery confirmed per order.
Questions on a mobile hydrogen refueler kit
What pressure does the Hyroad station dispense at?
The release does not say, and we do not guess. Ask the unit builder for the working pressure of every circuit before any part is chosen.
Does a liquid hydrogen unit need different parts from a compressed gas one?
It can. H2Tools says liquid hydrogen service calls for low temperature embrittlement to be considered. Give us the service temperature on each line so parts are not matched on size alone.
Can you quote a repeatable kit?
Yes. Send the sheet with tube sizes, thread types, pressures and temperatures. We quote it line by line, and grade and rating are confirmed per order.
Why not buy parts as each unit is built?
Piecemeal buying lets small substitutions creep in between units. One revised list keeps every unit to the same parts.
Building more than one skid?
Send the parts sheet once and we will price it as a set for you.
SUPERIOR FLUID SOLUTIONS
One skid, one list, one set of numbers.
Sources
- Hyroad Energy, “Hyroad Energy Deploys Hydrogen Refueling Station Enabling Fuel Access for Southern California Trucking Fleets,” PR Newswire, 29 July 2026. Supports the 1,000-kilogram liquid hydrogen tank, the single mobile unit, 45 transactions in the first full week, fuelling times under 25 minutes, the California and Texas network and that no dispensing pressure is stated. Company press release. prnewswire.com
- Toyota Motor North America, “Toyota Achieves Heavy-Duty Hydrogen Truck Milestones,” news release, 20 October 2026, via PR Newswire. Company publication. Supports the two mobile hydrogen fueling devices at North American Parts Center California and the planned permanent station. prnewswire.com
- U.S. Department of Energy, Alternative Fuels Data Center, “Hydrogen Basics.” Supports the H35 and H70 pressure classes, 5,000 and 10,000 psi, and light-duty and bus tank pressures. afdc.energy.gov
- U.S. Department of Energy, “Safe Use of Hydrogen.” Supports metals becoming brittle, rapid dissipation, and the need for ventilation and leak detection. energy.gov
- H2Tools, “Hydrogen Embrittlement.” Supports the variables listed and low temperature embrittlement for liquid hydrogen service. Publisher not named on the page. h2tools.org
- Superlok North America, SRVH high pressure relief valve and needle valve pages. Support the 6000 psig maximum operating pressure and the 10000 psi SHBNV listing. Manufacturer publications. superloknorthamerica.com
Technical note: The Hyroad release and the Toyota report establish what was deployed and when. Neither states a dispensing pressure, a fitting list or a supplier of fittings, and the Department of Energy and H2Tools pages describe hazards in general terms rather than certifying any part. The checklist is ours and is not a bill of materials for any station. Pressure ratings, temperature limits and grade for every part are confirmed per order.
Trademark disclaimer: Superlok® is a registered mark of its owner. Hyroad Energy and Toyota names appear as the property of their respective owners. Their use here identifies the sources referenced. Cross-references are made by form, fit, and function only.
